The resistances of 125 Ω strain gauge changes by 1 Ω for 4000 micro-strain. The gauge factor for strain gauge is

This question was previously asked in
ESE Electrical 2014 Paper 1: Official Paper
View all UPSC IES Papers >
  1. 1.5
  2. 2.0
  3. 2.5
  4. 3.0

Answer (Detailed Solution Below)

Option 2 : 2.0
Free
ST 1: UPSC ESE (IES) Civil - Building Materials
20 Qs. 40 Marks 24 Mins

Detailed Solution

Download Solution PDF

Concept:

The gauge factor is defined as the ratio of per unit change in resistance to per unit change in length.

Gauge factor 

Where ε = strain = ΔL/L

Calculation:

Given that, change in resistance (ΔR) = 1 Ω

Resistance (R) = 125 Ω

Micro strain (ε) = ΔL/L = 4000 μs

Gauge factor 