एक 480 MW, 3 फेज Y-संयोजित तुल्‍यकालिक जनरेटर में 0.8 के शक्ति गुणक पर 20 kV का रेटेड वोल्टेज है। पूर्ण भार रेटेड स्थितियों का संचालन करते समय लाइन धारा क्या होगी?

This question was previously asked in
ISRO (VSSC) Technical Assistant Electrical 2017 Official Paper
View all ISRO Technician Papers >
  1. 13.43 kA
  2. 17.3 kA
  3. 23.25 kA
  4. 27.36 kA

Answer (Detailed Solution Below)

Option 2 : 17.3 kA
Free
DRDO Technician Fitter (Rank Booster): Mini Mock Test
60 Qs. 60 Marks 45 Mins

Detailed Solution

Download Solution PDF

धारणा:

जहाँ,

P = MW में मशीन रेटिंग

VL = लाइन वोल्टेज

IL = लाइन धारा

Cosϕ = शक्ति गुणक

गणना:

दिया हुआ-

VL = 20 kV, cosϕ = 0.8, P = 480 MW

IL = 17.32 kA