A single-phase voltage-source-square wave inverter feeds pure inductive load. The waveforms of the load current will be:

This question was previously asked in
ISRO (VSSC) Technical Assistant Electrical 2016 Official Paper
View all ISRO Technician Papers >
  1. Sinusoidal
  2. Rectangular
  3. Trapezoidal
  4. Triangular

Answer (Detailed Solution Below)

Option 4 : Triangular
Free
DRDO Technician Fitter (Rank Booster): Mini Mock Test
60 Qs. 60 Marks 45 Mins

Detailed Solution

Download Solution PDF

The output of the single-phase voltage-source-square wave inverter, i.e. a square wave is fed to the inductive load.

The current in the inductor is given by  therefore when square voltage is

input the inductor current will be triangular.